{"product_id":"teleflex-arrow-cv-12703","title":"Teleflex Arrow CV-12703 Three-Lumen Central Venous Catheter Set, 7 Fr × 16 cm","description":"\u003cp\u003eThe Teleflex Arrow CV-12703 is a three-lumen central venous catheter set used to establish multi-port central venous access in adult ICU, surgical, and acute care patients. Once inserted, it provides three simultaneous, independent channels into the central venous circulation — each capable of delivering drugs, fluids, blood products, or parenteral nutrition, or monitoring central venous pressure, at the same time without mixing or cross-contaminating infusions between lumens.\u003c\/p\u003e\n\u003cp\u003eThe catheter is inserted using the Seldinger (guidewire) technique — the included 18Ga introducer needle accesses the target vein, the spring-wire guide is advanced through the needle, the tissue dilator tracks over the wire to open the insertion tract, and the catheter is loaded over the wire and advanced to the correct depth. The SecondSite™ adjustable hub is then used to fix the catheter to the skin at the chosen external length and secure it with the suture fastener.\u003c\/p\u003e\n\u003cp\u003eAt 16 cm, the CV-12703 is sized for right internal jugular and right subclavian access in most adult patients — placing the catheter tip in the distal superior vena cava or cavoatrial junction. This length is generally too short for left-sided internal jugular or left subclavian access, where a 20 cm catheter is typically required.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRadiopaque Polyurethane Construction -\u003c\/strong\u003e The catheter is made from medical-grade polyurethane with a radiopaque additive throughout the material. This allows the catheter shaft and tip to be clearly visualised on chest X-ray, confirming correct tip position at the cavoatrial junction without needing contrast or additional imaging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtra Thin-Wall (XTW) Introducer Needle - \u003c\/strong\u003eThe 18Ga XTW needle has a thinner wall than standard thin-wall needles — providing a larger internal diameter for the same outer gauge. This allows the .032\" spring-wire guide to pass through smoothly while the 18Ga outer diameter creates a smaller initial puncture in the vessel wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArrow Advancer Guidewire Control - \u003c\/strong\u003eThe spring-wire guide is supplied with the Arrow Advancer — a single-hand wire-feeding device that allows controlled, incremental advancement of the guidewire through the needle while the operator's other hand maintains needle stability. This reduces the risk of inadvertent wire withdrawal or excessive advancement during the exchange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecondSite Adjustable Hub System - \u003c\/strong\u003e\u003cspan\u003eThe two-piece SecondSite hub — fastener and catheter clamp — allows the external catheter length to be set precisely after insertion without re-positioning the catheter in the vein. The hub slides to the desired position and is locked, providing a suture point without damaging the catheter body at the fixation point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStaggered Triple-Port Distal Configuration - \u003c\/strong\u003e\u003cspan\u003eThe three lumen ports open at different points along the distal catheter — not at the same level. This staggers the exit points of drugs and fluids infusing through each lumen, reducing the risk of precipitation reactions between incompatible drugs that could otherwise meet at a shared intravascular exit point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColour-Coded Lumen Hubs \u0026amp; Clamps - \u003c\/strong\u003e\u003cspan\u003eEach of the three lumens is colour-coded at the hub — proximal (brown), medial, and distal — allowing instant visual identification of which port is being accessed at the bedside. Colour-coded clamps on each extension arm further prevent accidental opening of the wrong lumen during drug administration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"eyebrow\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"spec-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Number\u003c\/td\u003e\n\u003ctd\u003eCV-12703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatheter Size\u003c\/td\u003e\n\u003ctd\u003e7 French (Fr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter (OD)\u003c\/td\u003e\n\u003ctd\u003e2.5 mm (7 Fr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsertion Length\u003c\/td\u003e\n\u003ctd\u003e16 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Lumens\u003c\/td\u003e\n\u003ctd\u003e3 (Triple \/ Three-Lumen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003eStaggered distal ports — proximal, medial, and distal exit points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximal Lumen Hub Colour\u003c\/td\u003e\n\u003ctd\u003eBrown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatheter Material\u003c\/td\u003e\n\u003ctd\u003eRadiopaque polyurethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Markings\u003c\/td\u003e\n\u003ctd\u003eDepth markings along catheter shaft for insertion depth reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sec-label\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"sec-label\"\u003eSet Components\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpring-Wire Guide\u003c\/td\u003e\n\u003ctd\u003e.032\" (0.81 mm) dia. × 17¾\" (45 cm) — straight soft tip \/ J-tip; with Arrow Advancer™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntroducer Needle\u003c\/td\u003e\n\u003ctd\u003e18 Gauge × 2½\" (6.35 cm) Extra Thin-Wall (XTW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe\u003c\/td\u003e\n\u003ctd\u003e5 mL Luer-Slip — for venous blood aspiration confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTissue Dilator\u003c\/td\u003e\n\u003ctd\u003e8.5 Fr (2.8 mm) × 10.2 cm — tapered, passed over guidewire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDust Caps\u003c\/td\u003e\n\u003ctd\u003e3 × Non-Vented — one per lumen, maintains closed system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondSite™ Fastener\u003c\/td\u003e\n\u003ctd\u003eAdjustable hub — slides along catheter to skin surface, sets external length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondSite™ Catheter Clamp\u003c\/td\u003e\n\u003ctd\u003eLocks fastener at chosen depth — provides suture anchor without puncturing catheter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"sec-label\"\u003eClinical \u0026amp; Regulatory Data\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCVC Set — not a full procedural kit (no drape, no injection needles, no skin prep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAntimicrobial Coating\u003c\/td\u003e\n\u003ctd\u003eNone — standard (non-impregnated) catheter. For antimicrobial version, see CS-12703E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuidewire Technique\u003c\/td\u003e\n\u003ctd\u003eSeldinger (modified Seldinger) — standard CVC insertion method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Access Sites\u003c\/td\u003e\n\u003ctd\u003eRight internal jugular vein, right subclavian vein (16 cm length). Left-sided and femoral access requires longer catheter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended Use Duration\u003c\/td\u003e\n\u003ctd\u003eShort-term central venous access (up to 30 days per institutional policy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Population\u003c\/td\u003e\n\u003ctd\u003eAdult\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eSterile — single use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatex Content\u003c\/td\u003e\n\u003ctd\u003eLatex-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Marking\u003c\/td\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSales Quantity\u003c\/td\u003e\n\u003ctd\u003e10 sets per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eTeleflex Medical (Arrow International)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributor in India\u003c\/td\u003e\n\u003ctd\u003eShah Trading Corporation, Mumbai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"SHAH TRADING CORPORATION","offers":[{"title":"Default Title","offer_id":49513192292580,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/1573\/9876\/files\/ARROWCV-12703TRIPLELUMENCVC.jpg?v=1785150868","url":"https:\/\/www.stcsurgical.com\/products\/teleflex-arrow-cv-12703","provider":"SHAH TRADING CORPORATION","version":"1.0","type":"link"}