{"product_id":"fisher-paykel-rd900-neopuff-infant-t-piece-resuscitator","title":"Fisher \u0026 Paykel Healthcare RD900 Neopuff Infant T-Piece Resuscitator","description":"\u003cp data-end=\"551\" data-start=\"197\"\u003eThe Fisher \u0026amp; Paykel Neopuff™ RD900AEU is an infant T-piece resuscitator developed for controlled neonatal and infant respiratory support during resuscitation. It is designed to deliver consistent Peak Inspiratory Pressure (PIP) and Positive End-Expiratory Pressure (PEEP), helping clinicians provide more stable ventilation during critical neonatal care.\u003c\/p\u003e\n\u003cp data-end=\"891\" data-start=\"553\"\u003eUnlike conventional self-inflating bags, the Neopuff™ system allows predefined pressure settings before patient use, supporting controlled lung recruitment and helping reduce pressure variability during manual ventilation. The device is commonly used in delivery rooms, NICUs, special care baby units, and neonatal transport environments.\u003c\/p\u003e\n\u003cp data-end=\"1097\" data-start=\"893\"\u003eIts lightweight standalone construction, integrated manometer, and adjustable pressure controls make it suitable for rapid-response neonatal airway support where precision and repeatability are important.\u003c\/p\u003e\n\u003cp data-end=\"1236\" data-start=\"1099\"\u003e\u003cstrong data-end=\"1127\" data-start=\"1099\"\u003eShah Trading Corporation, Mumbai\u003c\/strong\u003e is a trusted supplier and distributor Fisher \u0026amp; Paykel Neopuff Infant T-Piece Resuscitator and other neonatal respiratory products across India.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1bqk1w5\" data-end=\"1264\" data-start=\"1243\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1262\" data-start=\"1246\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong data-end=\"1302\" data-start=\"1268\"\u003e* Controlled PIP \u0026amp; PEEP Delivery - \u003c\/strong\u003eEnables clinicians to preset inspiratory and end-expiratory pressures for more consistent neonatal ventilation.\u003cbr\u003e\u003cstrong data-end=\"1460\" data-start=\"1424\"\u003e* T-Piece Resuscitation Technology - \u003c\/strong\u003eProvides pressure-controlled respiratory support compared to variable manual bag compression systems.\u003cbr\u003e\u003cstrong data-end=\"1619\" data-start=\"1572\"\u003e* Supports Functional Residual Capacity (FRC) - \u003c\/strong\u003eConsistent PEEP delivery helps maintain lung volume and alveolar stability in neonates.\u003cbr\u003e\u003cstrong data-end=\"1751\" data-start=\"1717\"\u003e* Integrated Pressure Monitoring - \u003c\/strong\u003eBuilt-in medical-grade manometer allows continuous visualization of delivered airway pressures.\u003cbr\u003e\u003cstrong data-end=\"1887\" data-start=\"1857\"\u003e* Adjustable Oxygen Delivery - \u003c\/strong\u003eCompatible with oxygen blender systems for delivery ranging from room air to high oxygen concentrations.\u003cbr\u003e\u003cstrong data-end=\"2038\" data-start=\"2002\"\u003e* Pressure Relief Safety Mechanism - \u003c\/strong\u003eIncludes maximum pressure limitation to reduce risk of excessive airway pressure exposure.\u003cbr\u003e\u003cstrong data-end=\"2171\" data-start=\"2139\"\u003e* Compact \u0026amp; Lightweight Design - \u003c\/strong\u003eSuitable for bedside neonatal resuscitation, transport support, and delivery room use.\u003cbr\u003e\u003cstrong data-end=\"2297\" data-start=\"2268\"\u003e* Flexible Mounting Options - \u003c\/strong\u003eCan be mounted on infant warmers, rails, poles, incubators, or wall systems.\u003c\/p\u003e\n\u003ch2 data-section-id=\"sgends\" data-end=\"2418\" data-start=\"2387\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2416\" data-start=\"2390\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e* Ref No: RD900AEU\u003cbr\u003e* Product Type: Infant T-piece resuscitator\u003cbr\u003e* Application: Neonatal and infant resuscitation\u003cbr\u003e* Patient Group: Neonates and infants up to approximately 10 kg\u003cbr\u003e* Ventilation Method: Pressure-controlled T-piece ventilation\u003cbr\u003e* Pressure Parameters: Adjustable PIP and PEEP\u003cbr\u003e* Oxygen Delivery Range: 21% to 100% (with blender\/flow source)\u003cbr\u003e* Pressure Monitoring: Integrated manometer\u003cbr\u003e* Safety Feature: Maximum pressure relief valve\u003cbr\u003e* Mounting Compatibility: Pole, rail, wall, warmer, incubator\u003cbr\u003e* Manufacturer: Fisher \u0026amp; Paykel, New Zealand\u003cbr\u003e* Distributor in India: Shah Trading Corporation, Mumbai\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKit Includes: Neopuff Resuscitator RD900 + Gas Suuply Line 900RD009 + Neopuff Test Lung (RD020-01) + Neopuff T-Piece Circuit (RD1300-10) + Resuscitation Mask (RD803\/RD804\/RD805\/RD806\/RD807)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"3341\" data-end=\"3363\" data-section-id=\"1d0ux7\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3344\" data-end=\"3361\"\u003eProduct Usage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eConnect device to regulated gas source or blender then preset desired PIP and PEEP levels. Attach patient interface or resuscitation circuit to deliver assisted breaths using T-piece occlusion control. Continuously monitor pressure readings during resuscitation\u003c\/p\u003e","brand":"SHAH TRADING CORPORATION","offers":[{"title":"Default Title","offer_id":48889660440804,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/1573\/9876\/files\/Fisher_PaykelNeopuffInfantResuscitator-1.png?v=1778224707","url":"https:\/\/www.stcsurgical.com\/products\/fisher-paykel-rd900-neopuff-infant-t-piece-resuscitator","provider":"SHAH TRADING CORPORATION","version":"1.0","type":"link"}