{"product_id":"covidien-gia-stapler-with-dst-series-technology-gia8038s","title":"Covidien GIA Auto Suture Stapler with DST Series Technology, 80mm, 3.8mm - GIA8038S","description":"\u003cp\u003eGastrointestinal surgery depends on joining and dividing tissue quickly, cleanly and consistently. The Covidien GIA 80 stapler with DST Series technology does this in a single firing. It places staggered rows of staples on both sides of the intended cut line, then divides the tissue between them with an integrated knife.\u003c\/p\u003e\n\u003cp\u003eThe 80mm length covers a wide transection in one action. This suits bowel resections, side-to-side anastomoses and other soft-tissue procedures where a long, uniform staple line is needed. The 3.8mm staple height is chosen for tissue of moderate thickness. DST Series technology is designed to give the surgeon better control during clamping and firing, helping to keep the staple line consistent from one end to the other.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eShah Trading Corporation supplies the GIA8038S to hospitals, surgical centres, institutional buyers and distributors who need reliable access to Covidien surgical stapling products.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eKey Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e* Staple-and-divide in one action:\u003c\/strong\u003e Reduces the number of manual steps during resection and anastomosis.\u003cbr\u003e\u003cstrong\u003e* 80mm staple line:\u003c\/strong\u003e Handles longer transections without repositioning the instrument.\u003cbr\u003e\u003cstrong\u003e* 3.8mm staple height:\u003c\/strong\u003e Matched to tissue of intermediate thickness; surgeons choose the height based on tissue assessment.\u003cbr\u003e\u003cstrong\u003e* Staggered staple rows:\u003c\/strong\u003e Staples on each side of the cut line are offset, which supports secure tissue approximation along the whole length.\u003cbr\u003e\u003cstrong\u003e* DST Series technology:\u003c\/strong\u003e Engineered to improve staple-line consistency and handling during firing.\u003cbr\u003e\u003cstrong\u003e* Sterile, single-use instrument:\u003c\/strong\u003e Ready for the operating field with no reprocessing, which supports infection-control protocols.\u003cbr\u003e\u003cstrong\u003e* Titanium staples:\u003c\/strong\u003e Titanium is commonly used in surgical staples for its biocompatibility.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eDetailed Specification\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable style=\"width: 100.035%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width: 30.4089%;\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"width: 69.3813%;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eCovidien (Medtronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eReference No.\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eGIA8038S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eDisposable gastrointestinal anastomosis stapler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eTechnology\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eDST Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eStaple line length\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003e80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eStaple height\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003e3.8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003ePlaces staple rows and divides tissue in one firing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eStaple material\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eTitanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eSterility\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eSupplied sterile, single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eCovidien LLC, USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.4089%;\"\u003eDistributor in India\u003c\/td\u003e\n\u003ctd style=\"width: 69.3813%;\"\u003eShah Trading Corporation, Mumbai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\n\u003cbr\u003eHow It Is Used in the Real World\u003c\/h2\u003e\n\u003col dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose the right size.\u003c\/strong\u003e The surgeon assesses tissue thickness and picks the staple height and length. The 3.8mm option suits intermediate-thickness tissue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the instrument.\u003c\/strong\u003e The scrub team inspects the sterile pack, expiry date and reference number before opening it onto the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosition the tissue.\u003c\/strong\u003e The jaws are opened and the tissue is placed between them so the intended transection line sits within the 80mm staple zone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose and check.\u003c\/strong\u003e The jaws are closed and the clamp is verified. The surgeon confirms that tissue is correctly seated and the position is right.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire the stapler.\u003c\/strong\u003e Firing places the staple rows and advances the knife through the tissue in one smooth stroke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelease and inspect.\u003c\/strong\u003e The jaws are opened, the instrument is withdrawn, and the staple line is inspected for completeness and haemostasis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispose safely.\u003c\/strong\u003e The used instrument is discarded as clinical waste according to hospital policy. It must not be reprocessed or reused.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"SHAH TRADING CORPORATION","offers":[{"title":"Default Title","offer_id":67423963611364,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/1573\/9876\/files\/CovidienGIAStaplerGIA8038SProductImage.jpg?v=1790927930","url":"https:\/\/www.stcsurgical.com\/products\/covidien-gia-stapler-with-dst-series-technology-gia8038s","provider":"SHAH TRADING CORPORATION","version":"1.0","type":"link"}