{"product_id":"arrow-ez-io-power-driver-9058","title":"Arrow EZ-IO Power Driver, Intraosseous Vascular Access Driver (Ref No: 9058)","description":"\u003cp dir=\"ltr\"\u003eIn cardiac arrest, shock, burns or major trauma, veins can collapse and a standard cannula may take minutes the team does not have. The Arrow EZ-IO Power Driver is built for that moment. This handheld, battery-powered drill drives a specially designed needle through the bone surface and into the marrow cavity. Drugs and fluids then reach the central circulation through the bone's rich blood supply.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eArrow is a Teleflex brand, and EZ-IO is one of the most widely recognised intraosseous (IO) access systems in emergency medicine. Ref No 9058 is the reusable power driver. It works with separately supplied, sterile EZ-IO needle sets chosen for the patient's size and insertion site.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eEmergency departments, ambulance services, ICUs, military medical units and rapid-response teams use it as a fast, repeatable option when IV access is difficult or impossible.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eShah Trading Corporation supplies the EZ-IO Power Driver 9058 to hospitals, EMS providers, distributors and institutional buyers in India and overseas, with clear documentation and dependable stock handling. We also supply the wider Arrow, Teleflex and Fisher \u0026amp; Paykel ranges.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\" aria-level=\"5\"\u003eKey Features\u003c\/h3\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowered insertion:\u003c\/strong\u003e A motorised drive replaces the manual force of older IO methods, giving a controlled, consistent insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for speed:\u003c\/strong\u003e Designed to establish vascular access in seconds when peripheral IV attempts have failed or are unrealistic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReusable driver, disposable needles:\u003c\/strong\u003e One driver serves many patients, while each patient gets a new sterile needle set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-handed trigger operation:\u003c\/strong\u003e The clinician can steady the limb with the free hand and concentrate on positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic needle-set pick-up:\u003c\/strong\u003e The needle set attaches to the driver tip magnetically, so it can be loaded straight from its protective cap without touching the needle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact and portable:\u003c\/strong\u003e Small enough for a crash cart, trauma bag or ambulance kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-contained battery power:\u003c\/strong\u003e No cord is needed, so it suits field use and emergency storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with multiple needle lengths:\u003c\/strong\u003e Different needle sets cover small children through larger adults, and different anatomical sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstablished clinical use:\u003c\/strong\u003e Widely referenced in resuscitation protocols and emergency training programmes worldwide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 dir=\"ltr\" aria-level=\"5\"\u003eDetailed Specification\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eArrow (Teleflex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference \/ Part No.\u003c\/td\u003e\n\u003ctd\u003e\u003cspan dir=\"ltr\"\u003e9058\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eBattery-powered intraosseous access driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDriver reusability\u003c\/td\u003e\n\u003ctd\u003eReusable power unit; needle sets are single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle-set compatibility\u003c\/td\u003e\n\u003ctd\u003eEZ-IO needle sets in multiple lengths (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eInternal battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess sites\u003c\/td\u003e\n\u003ctd\u003eAs defined in the manufacturer's IFU and local protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eDriver supplied non-sterile; needle sets supplied sterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended users\u003c\/td\u003e\n\u003ctd\u003eTrained physicians, paramedics, nurses and emergency responders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCare settings\u003c\/td\u003e\n\u003ctd\u003eEmergency, critical care, prehospital, military and disaster response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufactured For\u003c\/td\u003e\n\u003ctd\u003eTeleflex Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistributor in India\u003c\/td\u003e\n\u003ctd\u003eShah Trading Corporation, Mumbai\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\" aria-level=\"5\"\u003eHow It Is Used in the Real World\u003c\/h3\u003e\n\u003col dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDecide that IO access is needed.\u003c\/strong\u003e The clinician determines that peripheral IV access is delayed, failed or impractical, following local protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose the needle set.\u003c\/strong\u003e Select the length by patient size, tissue depth and insertion site, as the IFU describes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the site.\u003c\/strong\u003e Identify the anatomical landmark, clean the skin and put on gloves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad the driver.\u003c\/strong\u003e Hold the driver against the needle set while it is still in its protective cap. The magnet secures it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert.\u003c\/strong\u003e Position the needle perpendicular to the bone, squeeze the trigger and apply steady, gentle pressure until the needle seats in the marrow space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the driver and stylet.\u003c\/strong\u003e Detach the driver and withdraw the inner stylet, leaving the catheter in place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm placement.\u003c\/strong\u003e Secure the catheter, check that it is stable and flush with saline as directed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart therapy.\u003c\/strong\u003e Give fluids and medication as ordered, using a pressure bag or syringe where needed. Manage pain in conscious patients per protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the transition.\u003c\/strong\u003e IO access is temporary. Remove the needle set within the time limit in the IFU once reliable IV access is available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset the driver.\u003c\/strong\u003e Clean it per the manufacturer's guidance and return it to the kit, ready for the next case.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e","brand":"SHAH TRADING CORPORATION","offers":[{"title":"Default Title","offer_id":68454270009572,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/1573\/9876\/files\/ARROWEZ-IOPOWERDRIVER.jpg?v=1795416309","url":"https:\/\/www.stcsurgical.com\/products\/arrow-ez-io-power-driver-9058","provider":"SHAH TRADING CORPORATION","version":"1.0","type":"link"}